CHEMILYZER
H-200
Automatic Hematology Analyzer
|
|
|
 |
|
Description |
 |
|
Specifications:
- Assay methods: End Point, Kinetic, Fix time etc.
- Principle: Photoelectric colorimetry
- Light Source: Halogen lamp 12V/20W
- Photometry range: 0~3.2Abs
- Resolution: 0.0001Abs
- Wavelength: 340nm\405nm\450nm\492nm\510nm\546nm\578nm\630nm\700nm\800nm
- Throughput: 200 tests/hour
- Reagent tray: 60 reagent positions (include1detergent position,1 dilution position)
- Sample tray: 71sample positions, standard, QC, STAT positions
- Reaction tray: 120 reaction cuvettes
- Sample volume: 2~100ul, with 0.1ul increment
- Reagent volume: R1:10~500uL, R2: 10~500uL,with 0.5uL increment
- Minimum reaction volume: 150uL
- Maximum reaction time: 10 minutes
- Water Consumption: 5L/hour under working status
- Clean unit: 8-step auto-washing system with detergent
- Calibration: Calibration reset, select best test point by reaction curve, no need second calibration Line/non-line;multi-standards assay
- Control rules: Westgard multi-rule, Cumulative sum check, Twin plot 3 level controls for each ifem, analyxing and printing QC analysis diagram
- Temperature control: incubator 37±0.1℃
- Power supply: AC 230(1±10%)V, 50/60Hz, 500VA
- Ambient: Operating temperature: 10~30℃
- Relative humidity: ≤85%
- Atmospheric pressure: 86~106kPa
Features
- 24 hour non-stop cooling system to ensure reagent at 2-8℃
- Durable ceramic syringes to ensure accuracy & precision
- High accurate optical system
- Collision protection in both vertical and horizontal directions, stop & alarm automatically once touching barrier, not affect former tests
- Automatic eligible cuvettes detection & selection
- Select best test point by reaction curve, create new factor automatically
- Support LIS interface
Accurate Sampling(Sample/Reagent) System
- Collision protection
- Liquid level detection
- Internal and external probe washing
- Probe depth adjustment automatically
High performance mixer design
- Absence of cross contamination
- Optimal homogenization in minimum time
- Mixing immediately after dispensing of sample and the second reagent
Stable Optical System
- High accurate, close, static state optical system
- Spot photometry with high speed digital transmission system
- Durable cuvettes
- 8-step auto-washing system with detergent and deion-water to ensure cuvettes clean and decrease cross contamination
- 120 reaction cuvettes located in a constant temperature incubator
- Low consumption, open reagent design
Multi-function sample/reagent tray
- 60 reagent positions, support 25mL, 50 mL reagent bottle type.
- 45 sample positions including routine, stat, control and standard
- Various primary tubes and special cups can be used
- Up to 20 virtual sample tray can be programmed
- 24 hours nonstop cooling system with peltier element
Dynamic and real time display of running status
- Running status of reagent tray, sample tray and reaction tray
- Real time monitoring of reagent residual volume
- Intelligent carry over setting to adjust test sequence, STAT test priority
- Probe depth adjustment automatically
- Real time monitoring of reaction curve
- Real time diagnosis of system working status
|
|
|
|